Request a Quote

* Required fields










Message / Order details:
Sending...

1-800-794-5883
Translate Mod Tronic Instruments Ltd.
Select Language


Apply filters
Categories
Clear Filters
Filter Results
Input Type
 AC Input (12)
 DC Input (1)
Setpoint Type
 Adjustable (6)
 Factory Set (8)
Power Supply
 120V AC or 24V AC/DC (5)
 12–40 VDC Loop (0)
 24V AC/DC (2)
 24 VDC (1)
 24 V DC loop-powered (12–32 V) (1)
 240 V AC (AG solid-state models) (1)
Approvals
 CE, UL Listed - USA & Canada (7)
 UL Listed - USA & Canada (4)
 None (1)
 CE (1)
 CE, GL, CSA (0)
 UL Recognized - USA & Canada (1)
 RoHS (0)
Output Type
 Solid-state AC switch (1)
 Solid-state DC switch (1)
 SPDT dry-contact relay (10)
 SPST dry-contact relay (3)
 SPST wet-contact relay (120 V AC) (1)
 4–20 mA analog (1)
 0–5 V DC analog (1)
 0–10 V DC analog (1)
Maximum Wire Bundle Diameter
 0.75 in (19.1 mm) (5)
 1.25 in (31.75 mm) (3)
 1.30 in (33.0 mm) (1)
 1.76 in (44.7 mm) (3)
 4.00 in (101.6 mm) (1)
Categories
Clear Filters
Filter Results
Input Type
 AC Input (12)
 DC Input (1)
Setpoint Type
 Adjustable (6)
 Factory Set (8)
Power Supply
 120V AC or 24V AC/DC (5)
 12–40 VDC Loop (0)
 24V AC/DC (2)
 24 VDC (1)
 24 V DC loop-powered (12–32 V) (1)
 240 V AC (AG solid-state models) (1)
Approvals
 CE, UL Listed - USA & Canada (7)
 UL Listed - USA & Canada (4)
 None (1)
 CE (1)
 CE, GL, CSA (0)
 UL Recognized - USA & Canada (1)
 RoHS (0)
Output Type
 Solid-state AC switch (1)
 Solid-state DC switch (1)
 SPDT dry-contact relay (10)
 SPST dry-contact relay (3)
 SPST wet-contact relay (120 V AC) (1)
 4–20 mA analog (1)
 0–5 V DC analog (1)
 0–10 V DC analog (1)
Maximum Wire Bundle Diameter
 0.75 in (19.1 mm) (5)
 1.25 in (31.75 mm) (3)
 1.30 in (33.0 mm) (1)
 1.76 in (44.7 mm) (3)
 4.00 in (101.6 mm) (1)

Ground Fault Sensors

Ground-fault relays detect leakage current and change their output contacts when a selected trip point is reached. Ground-fault transducers provide a proportional analog signal for a controller, meter or data logger. Compare AC or DC input, output type, trip range, supply and maximum wire-bundle diameter to select a suitable sensor for your application.

Wire-bundle filters show the maximum supported bundle diameter stated for each family. Check the product specifications and installation instructions for the complete assembly and conductor arrangement.

TitleImageBrandInput TypeLeakage Current / Trip RangeSetpoint TypePower SupplyApprovalsNormally
In Stock
 
AG Series Ground Fault RelaysAG Series Ground Fault RelaysNK TechnologiesCE; UL Recognition configuration-dependentAC Input5–100 or 80–950 mA; 5/10/30 mA tri-setFactory-set or tri-set jumper120 V AC or 24 V AC/DC; 240 V AC solid-state optionStock
 Compare
AG1-FM Series Ground Fault RelaysAG1-FM Series Ground Fault RelaysNK TechnologiesCE, UL/cUL ListedAC Input30–100 mA auto-reset; 5–100 mA latchingFactory-set120 V AC or 24 V AC/DCStock
 Compare
AGF-FM Series Ground Fault RelaysAGF-FM Series Ground Fault RelaysNK TechnologiesCE, UL/cUL ListedAC Input5 or 20 mA fixedFactory-set120 V ACStock
 Compare
AGK-FM Series Ground Fault RelayAGK-FM Series Ground Fault RelayNK TechnologiesCE, UL/cUL ListedAC Input5 mA fixedFactory-set120 V ACStock
 Compare
AGL Series Ground Fault RelaysAGL Series Ground Fault RelaysNK TechnologiesCE, UL/cUL ListedAC Input5–100 or 80–950 mA; 5/10/30 mA tri-setFactory-set or tri-set jumper120 V AC or 24 V AC/DCStock
 Compare
AG-LC Series Large-Core Ground Fault RelaysAG-LC Series Large-Core Ground Fault RelaysNK TechnologiesUL/cUL ListedAC Input30–1500 mA or 1–5 AAdjustable or factory-set (model dependent)120 V AC or 24 V AC/DCStock
 Compare
AGLD Series Ground Fault Relays with Digital DisplayAGLD Series Ground Fault Relays with Digital DisplayNK TechnologiesCE, UL/cUL ListedAC Input5–100 or 80–950 mA, adjustableAdjustable (pot with LED display)24 V AC/DCStock
 Compare
AGL-MAR Series Ground Fault Relay for MarinasAGL-MAR Series Ground Fault Relay for MarinasNK TechnologiesCE, UL/cUL ListedAC Input30/100 mA, field-selectableAdjustable120 V ACStock
 Compare
AGU Series Ground Fault RelayAGU Series Ground Fault RelayNK TechnologiesUL/cUL ListedAC Input5 mA fixedFactory-set120 V ACStock
 Compare
AGV Series Ground Fault Relays for VFD LoadsAGV Series Ground Fault Relays for VFD LoadsNK TechnologiesUL/cUL ListedAC Input30/50/100 mA, field-selectableAdjustable120 V AC or 24 V AC/DCStock
 Compare
DG Series DC Ground Fault RelaysDG Series DC Ground Fault RelaysNK TechnologiesNoneDC Input5–40 mA DCFactory-set24 V DCStock
 Compare
AGT-FD Series Ground Fault TransducersAGT-FD Series Ground Fault TransducersNK TechnologiesCE, UL/cUL ListedAC Input0–100 mANot applicable (measurement transducer)24 V AC/DCStock
 Compare
AGT-FL Series Ground Fault TransducersAGT-FL Series Ground Fault TransducersNK TechnologiesUL/cUL ListedAC Input0–50 or 0–100 mANot applicable (measurement transducer)24 V DC loop-powered (12–32 V)Stock
 Compare

Mod Tronic Instruments Limited
1 Delta Park Blvd #12
Brampton, ON L6T 5G1
Phone: 905-457-6322 or 1-800-794-5883
Fax: 905-457-4716 or 1-800-830-7122
Brampton
Halifax
Regina
Edmonton
905-457-6322
902-422-0978
306-359-1476
780-459-2690
Montreal
Winnipeg
Calgary
Vancouver
514-848-7205
204-895-2038
403-236-2909
604-224-9547