BFS-10-N-EXI Intrinsically Safe Flow Switches


The Barksdale BFS-10-N-EXI extends the BFS-10-N variable-area flow-switch family to intrinsically safe hazardous-area applications. The non-indicating, spring-loaded design provides adjustable flow switching in any mounting position.

Select the exact connection, wetted material and switching range for the application. Hazardous-area suitability depends on the certified configuration, temperature class, nameplate and associated intrinsically safe circuit.


Select & Configure Model
Base Model #Medium / ServiceSwitching RangeProcess ConnectionPressure LimitSwitch ContactsConfigure Part #
 
BFS-10-N-EXICompatible liquids; intrinsically safeSelected BFS-10-N rangesG1/4, G1/2 or G1Connection/material dependentCertified intrinsically safe circuit
Measuring Range:

Selected BFS-10-N ranges; confirm the certified configuration and medium.

Temperature Limit:

Hazardous-area temperature limits depend on temperature class and nameplate; do not assume the general HT rating applies.

Approvals:

ATEX TÜV 20 ATEX 248479 X; IECEx TUN 20.0003 X. Observe specific conditions of use.

Switch Type:

Adjustable magnetic reed flow switch; NO or change-over contacts according to model.

Mounting Orientation:

Any mounting position; observe flow direction and installation instructions.

Pressure Limit:

Mechanical BFS-10-N limits depend on connection/material; confirm the selected EXI model.

Ambient Temperature :

−40 to +75 °C; observe the operating instructions and certified conditions.

Electrical Rating:

Ui ≤28 V; Ii ≤110 mA; Pi ≤0.84 W. Use a suitable certified intrinsically safe switch amplifier.

Body Material:

Brass or stainless steel; see datasheet for wetted components.

Enclosure Rating:

IP65 with the specified plug; observe certified installation conditions.


The current operating instructions identify Ex ia IIB T6 Ga and Ex ia IIIC T100 °C Da protection with conditions of use. Only connect through a suitable certified intrinsically safe switch amplifier. Follow the permitted electrical parameters, installation requirements and temperature limits in the instructions.

The family datasheet is supplied for mechanical reference. Its general high-temperature and contact ratings do not supersede EXI certified limits. Confirm the exact approved contact arrangement and complete order code with Mod-Tronic; the general family datasheet excludes certain change-over/connection combinations from ATEX availability. Confirm availability with your inquiry.


Mod Tronic Instruments Limited
1 Delta Park Blvd #12
Brampton, ON L6T 5G1
Phone: 905-457-6322 or 1-800-794-5883
Fax: 905-457-4716 or 1-800-830-7122
Brampton
Halifax
Regina
Edmonton
905-457-6322
902-422-0978
306-359-1476
780-459-2690
Montreal
Winnipeg
Calgary
Vancouver
514-848-7205
204-895-2038
403-236-2909
604-224-9547