Series DL7 Differential Pressure Data Logger


Also Measures and Logs Temperature, Self-Powered, 2-Channel, Compact

Monitor and Record low differential pressures and temperature with the Model DL7 Differential Pressure Data Logger. Unit includes an on-board thermistor for ambient temperature measurement. Sampling rates are user selectable from 0.04 s to 8 hrs with First-in first-out or Fill-then-stop sampling options. Loggers can store up to 21,500 readings and operate totally independently from any external power supply with built-in lithium battery. Use Model DL200 Windows® software (sold separately) to quickly program the logger or upload data to a computer. The Series DL7 logger is ideal for monitoring air duct velocity, testing and balancing HVAC systems, or verifying room pressure.


Select & Configure Model
Base Model #AccuracySampling RatesRangePower RequirementsApprovalsNormally
In Stock
Configure Part #
 
DL70±0.05" w.c. (up to 2" range); ±0.1" w.c. (5" and 10" range).Selectable from 0.04 seconds to 8 hours.-40 to 158°F (-40 to 70°C), 0 to 95% RH, non-condensing.3.6 V TL5134 lithium metal battery, internal, factory replaceable.CEInquire
DL71±0.05" w.c. (up to 2" range); ±0.1" w.c. (5" and 10" range).Selectable from 0.04 seconds to 8 hours.-40 to 158°F (-40 to 70°C), 0 to 95% RH, non-condensing.3.6 V TL5134 lithium metal battery, internal, factory replaceable.CEInquire
DL72±0.05" w.c. (up to 2" range); ±0.1" w.c. (5" and 10" range).Selectable from 0.04 seconds to 8 hours.-40 to 158°F (-40 to 70°C), 0 to 95% RH, non-condensing.3.6 V TL5134 lithium metal battery, internal, factory replaceable.CEInquire
DL75±0.05" w.c. (up to 2" range); ±0.1" w.c. (5" and 10" range).Selectable from 0.04 seconds to 8 hours.-40 to 158°F (-40 to 70°C), 0 to 95% RH, non-condensing.3.6 V TL5134 lithium metal battery, internal, factory replaceable.CEInquire
DL710±0.05" w.c. (up to 2" range); ±0.1" w.c. (5" and 10" range).Selectable from 0.04 seconds to 8 hours.-40 to 158°F (-40 to 70°C), 0 to 95% RH, non-condensing.3.6 V TL5134 lithium metal battery, internal, factory replaceable.CEInquire

Mod Tronic Instruments Limited
1 Delta Park Blvd #12
Brampton, ON L6T 5G1
Phone: 905-457-6322 or 1-800-794-5883
Fax: 905-457-4716 or 1-800-830-7122
Brampton
Halifax
Regina
Edmonton
905-457-6322
902-422-0978
306-359-1476
780-459-2690
Montreal
Winnipeg
Calgary
Vancouver
514-848-7205
204-895-2038
403-236-2909
604-224-9547

Init - _SESSION: [] Init - paramsURL: {"ext":"products-by-category","id":"5","var":"31","var2":"201","var3":"616"}