Series DMF Digital Mass Flow Controller


Programmable, RS485 Interface, Up To 500 psig, ±1% Accuracy

Program, record, analyze, and control flow rates of various gases with Series DMF Digital Mass Flow Controller. Controllers are designed with straight tube sensors with restrictor flow elements to ensure laminar gas flow for accurate and repeatable results. Series DMF are unaffected by temperature and pressure variations. Controllers can be programmed for various control functions including flow set point, totalizer, stop totalizer, totalize from preset flow, stop and preset total, auto zero, and more. Auto zero feature utilizes an automatic balancing circuit that virtually eliminates drift of zero and span. In addition, Series DMF controllers have two dry contact closures to operate pumps, valves, or other process equipment.

The Series DMF features an auto tune function to optimize control response for a specific gas under actual process conditions. Self diagnostic tests are run at power up to ensure the controller is in optimum working condition. Calibration information for up to 10 gases and conversion factors for up to 256 different gases are stored in memory. High and low gas flow alarm limits are programmed via RS-485 interface. Software supports programmable flow modes, allowing execution of custom programming of up to ten steps.


Select & Configure Model
Base Model #DescriptionNormally
In Stock
Configure Part #
 
DMF-41402Digital mass flow controller, range 0-20 sccm. Specified flow range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg.Inquire
DMF-41403Digital mass flow controller, range 0-50 sccm. Specified flow range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg.Inquire
DMF-41404Digital mass flow controller, range 0-100 sccm. Specified flow range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg.Inquire
DMF-41405Digital mass flow controller, range 0-200 sccm. Specified flow range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg.Inquire
DMF-41406Digital mass flow controller, range 0-500 sccm. Specified flow range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg.Inquire
DMF-41407Digital mass flow controller, range 0-1 LPM. Specified flow range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg.Inquire
DMF-41408Digital mass flow controller, range 0-2 LPM. Specified flow range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg.Inquire
DMF-41409Digital mass flow controller, range 0-5 LPM. Specified flow range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg.Inquire
DMF-41411Digital mass flow controller, range 0-15 LPM. Specified flow range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg.Inquire
DMF-41431Digital mass flow controller, range 0-30 LPM. Specified flow range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg.Inquire
DMF-41433Digital mass flow controller, range 0-50 LPM. Specified flow range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg.Inquire
DMF-41842Digital mass flow controller, range 0-100 LPM. Specified flow range is for an equivalent flow of nitrogen at 70°F (21°C) @ 760 mm Hg.Inquire

Mod Tronic Instruments Limited
1 Delta Park Blvd #12
Brampton, ON L6T 5G1
Phone: 905-457-6322 or 1-800-794-5883
Fax: 905-457-4716 or 1-800-830-7122
Brampton
Halifax
Regina
Edmonton
905-457-6322
902-422-0978
306-359-1476
780-459-2690
Montreal
Winnipeg
Calgary
Vancouver
514-848-7205
204-895-2038
403-236-2909
604-224-9547

Init - _SESSION: [] Init - paramsURL: {"ext":"products-by-category","id":"4","var":"229","var2":"232","var3":"723"}