CTA2, SCTA2, CTA2-RMS & SCTA2-RMS Series Current Transducers


CTA2, SCTA2, CTA2-RMS & SCTA2-RMS Series

The 4-20 mA Output Analog Current Sensors are designed for use in any AC current monitoring application in which you are looking to monitor a particular piece of equipment. The “Average” style current sensors should be used in applications where the Sinusoidal waveform has no distortion or noise on the conductor being monitored. Applications may include monitoring a resistive type load such as an incandescent light bulb, heating element as well as any single speed linear load. Note that the “True RMS” sensors are able to be used in all applications since the “True RMS” current sensors provide the best overall accuracy and should be used in applications which includes Variable Frequency Drives, Switching Power Supplies, Computers and Data Centers, Electronic Ballasts, SCR’s, and Variable Speed Loads. For currents monitored above 250 Amps, the CTA2-5 and SCTA2-5 are ideal for use with a step down Ratio:5A Output CT (Current Transformer) in stepping down current in a monitored conductor to a proportional 0 to 5A output signal. The current sensors are available in both solid and split-core versions which also includes a Patented (Pat. No. US 7,416,421) 35 mm Din Rail mounting foot for easy installation in panel mount applications. The solid-core versions are a great choice for new installations or OEM applications in which cost sensitivity, lower trip points and environmental issues like dust and moisture may be of concern. The split-core version of the current sensors work great in retrofit applications and for use on service technicians vehicles since one or two parts will work in most applications and can be easily installed without disconnecting any wires.


Select & Configure Model
Base Model #Case StyleSensing Aperature SizeOutput SignalFrequency RangeResponse TimePower SupplyNormally
In Stock
Configure Part #
 
A/CTA2-5Solid Core 0.75”4 to 20 mA40 to 1KHz< 600 mS (Rise and Fall Time)8.5 to 30 VDCInquire
A/CTA2-50Solid Core 0.75”4 to 20 mA40 to 1KHz< 600 mS (Rise and Fall Time)8.5 to 30 VDCInquire
A/CTA2-250Solid Core 0.75”4 to 20 mA40 to 1KHz< 600 mS (Rise and Fall Time)8.5 to 30 VDCInquire
A/SCTA2-5Split Core0.75”4 to 20 mA40 to 1KHz< 600 mS (Rise and Fall Time)8.5 to 30 VDCInquire
A/SCTA2-50Split Core0.75”4 to 20 mA40 to 1KHz< 600 mS (Rise and Fall Time)8.5 to 30 VDCInquire
A/SCTA2-200Solid Core 0.75”4 to 20 mA40 to 1KHz< 600 mS (Rise and Fall Time)8.5 to 30 VDCInquire
A/CTA2-50-RMSSolid Core 0.75”4 to 20 mA15 to 100 Hz600 mS (Rise Time) and 2800 mS (Fall Time)8.5 to 30 VDCInquire
A/CTA2-250-RMSSolid Core 0.75”4 to 20 mA15 to 100 Hz600 mS (Rise Time) and 2800 mS (Fall Time)8.5 to 30 VDCInquire
A/SCTA2-50-RMSSplit Core0.75”4 to 20 mA15 to 100 Hz600 mS (Rise Time) and 2800 mS (Fall Time)8.5 to 30 VDCInquire

Mod Tronic Instruments Limited
1 Delta Park Blvd #12
Brampton, ON L6T 5G1
Phone: 905-457-6322 or 1-800-794-5883
Fax: 905-457-4716 or 1-800-830-7122
Brampton
Halifax
Regina
Edmonton
905-457-6322
902-422-0978
306-359-1476
780-459-2690
Montreal
Winnipeg
Calgary
Vancouver
514-848-7205
204-895-2038
403-236-2909
604-224-9547

Init - _SESSION: [] Init - paramsURL: {"ext":"products-by-category","id":"14","var":"50","var2":"138","var3":"607"}